Numerical control system and machining center are common breakdown interlocution

  • Time:
  • Click:135
  • source:JANEZH CNC Machining
1, parameter loses suddenly (0MD system) FANUC expert hello: Machining center of a horizontal of my company appears in move 930 AL and CRT show chaos piles up a form, close afresh machine all parameter after switching on the mobile phone are missing. Be in next switch on the mobile phone machine tool of parameter of the input below condition can move normally. Is knowing this why? Irritated ask you to offer support and help. Thanks here! Answer: Parameter is lost suddenly, may with memory board, batteries or exterior interference are concerned, 930 also explain exterior likelihood has interference to bring about CPU the job is abnormal, occurrence system calls the police. Also do not eliminate advocate board or other PCB breakdown. 2, 926 call the police (18i) thanks you to reply to before me two interrogative. Showed another machining center to appear 926 call the police, divide on the LCD that the system controls later call the police outside information, do not have any indication (electronic-controlled at that time the temperature inside ark is higher) , somehow, long to solve. Thank! Answer: 926 call the police (FSSB calls the police) reason and the FSSB that handle join CNC and servo amplifier (servo is serial bus line) malfunction. The FSSB that if join,axle control blocks, occurrence problem of cable and servo amplifier, can produce this to call the police. ? ? Affirm breakdown position uses the LED judgement on servo amplifier. Can 7 paragraphs of LED on use servo amplifier affirm the position of breakdown? ? The power source of servo amplifier if the power source of amplifier of a certain servo appears breakdown, produce FSSB to call the police. As a result of enlarge breakdown implement voltage of control power source drops, or of coder cable + 5V ground connection, or other reason causes power source trouble, cause FSSB to call the police. ? ? Change if axle control card diagnoses an axle control to block existence breakdown by above measure, change advocate the axle control on CPU board gets stuck. 3, call the police (0imate-B) hello: ? Shallow lens of 8  that return Lian seeks  to make? of impaludism of new moon of jab of  of  of  of accept of  cheek chasm a lathe of my company often appears recently 920, 911, 930 call the police, among them 930 most, provide technical support please.

My general is obliged.

Address; Shandong saves bank company of piston of continent city Hui Min county returns: 911SRAMPARITY:(BYTE1) produces mistake of odd even desired result in RAM of partial program memory. Completely clear RAM, or change SRAM module or advocate board. Next reset parameter and data. 920SERVOALARM(1-4AXIS) this is servo calls the police (the first to four-axle) . Appeared monitoring calls the police or mistake of odd even of the RAM inside servo module. Change please advocate board the 930CPUINTERRUPTCPU of servo control module that go up calls the police blame is normal interrupt. Advocate board or CPU check is bad. Can affirm breakdown part through exchanging the method of the component, additional machine tool ground connection, exterior interference also must bring to sb's attention 4, parameter cannot adapt (BJ-FANUCOi-MB) hello, my company has the far east opportunity that a new machine produces for Taiwan, after new machine has been installed, try machine, discover B axis cannot be answered 0, turn to answer 0 switch part to begin decelerate when B axis, but turn to be able to appear before long 90 call the police, cannot answer 0, knowing is what reason, help please! Many thanks! Answer: 90 call the police specification: Should not satisfy " on the way that returning reference point, measure in order to be equivalent to positional deviation (DGN.

300) when the speed that is more than 128 pulse returns reference point, CNC was received once at least 1 turn the condition of signal, when undertaking returning reference point, appear this calls the police. Check: 1.

Return 0 rate.

2.

Turn signal? 5, machining center (FANUC-18iM) machine tool is in out of service switchs on the mobile phone after period of time, appear call the police: 701: OVERHEAT: FANMOTOR is breakdown of CNC system cooling fan via checking this to call the police, but it is normal to discover fan runs after the examination, call the police indelible all the time drop. Have only finally parameter the #0 of 8901 by "0" instead "1" , screen drops this to call the police. The hope can be helped solve, thank! Answer: Fan is bad, but OK still and rotational, can buy to change newly only. Common breakdown interlocution 6, the machine tool calls the police (FANUC-18) calls the police in the machine tool after main shaft overload, call the police date is 751, module of main shaft servo calls the police how is date repaired excuse me for AL-73. Answer: Signal of electric machinery sensor breaks a string. (The case that call the police produces when excitation of 1) electric machinery is shut (A) parameter set has affirm sensor set parameter by accident. (B) cable breaks a line to change please cable. (C) sensor adjusts breakdown to undertake the adjustment of sensor signal please. When cannot be being adjusted or when signal observation is less than, change please join cable and sensor. (D)SPM breakdown changes please SPM or SPM control printed circuit board. (When 2) touchs cable (main shaft moves etc) happen calling the police may be lead breaks a string, change please cable. When cutting oil invades connector part, undertake cleaning please (the case that call the police produces when 3) electric machinery rotates (the breakdown of cable screen processing between A) sensor and SPM affirms cable screen is handled. (If arrive from sensor between SPM,the dynamical line colligation of B) and servo electric machinery arrived one case cable and colligation of line of power of servo electric machinery arrived one case, part please colligation. 7, 351 call the police (one machining center of Oi-M) , OI-M system, NC controls X, y, z, b4 axis, b axis is rotor. Breakdown phenomenon: In treatment, appear 351 call the police, and all be in N5H6Z344.

2 block are in, but this paragraph dictates without B axis job. After occurrence breakdown, 4 axes module all appears "-" shows. After new electrify normal, after working for some time, appear again this breakdown. Now average every occurrence 2-3 is answered. Solve: It is through diagnosing picture 0203#5#6 1, breakdown limits is 1: Signal cable connection is bad; 2 coder, advocate board, servo module hardware is undesirable. Because weigh,trouble can remove temporarily after rising, can eliminate 1. In the light of 2, we coder, advocate board, the outlet of servo module was inserted again, effect of it doesn't matter, breakdown still has. Ask you to be analysed, how should we do next answer: Basically check from 1 place, concern with signal cable, check the signal cable of the axis that call the police, look in when to have shift (often be in other axis movable type, the cable of this axis is procrastinated to move) . If cable is long-term be folded to come over to fold the past, can contact bad, call the police to be met nonsked appear. Can change only at that time new cable. 8, 408# calls the police at the same time with 409 # processing (FANUC0MD) machine tool appears 408 have a few kinds with the 409 reasons that call the police, give advice or comments please answer: Appear unlikelily at the same time commonly 408, 409 call the police. 408 it is communication undesirable, it is main shaft amplifier and system (memory board) between cannot correspond. It is main shaft amplifier does not have report commonly, or interface became bad 409 call the police, it is main shaft amplifier appeared to call the police number. Call the police specificly number shows on amplifier. 9, fan (0i-mate-TB) system occurrence "611, after 9113" date calls the police, do not turn via checking fan of cooling fin of power source module, change work normally after the fan of another normal movement. Affirm fan is bad. Buy same kind after fan changes, still appear afore-mentioned calling the police (fan runs normally) , although same manufacturer is produced,discover this fan via the examination but electric current than 0 original.

1A became big 0.

03A, again will the fan that goes up with module of main shaft drive carries out exchange, appear no longer "611, 9113" date calls the police, but on CRT occurrence "FAN" twinkles, do not affect treatment. Ask whether of fan detect not since the detecting element of thermal resistor and so on, is voltaic size merely detect just? Answer: Had better buy the fan CRT that is the same as model to go up because there still is an exterior fan to have a problem on carbon fin of module of main shaft drive,occurrence "FAN" twinkles is 10, 971 call the police! (BJFANUC0i-MateTB) this machine tool is the car of CAK6150D numerical control that factory of Shenyang machine tool produces, often appear in running a course automatically 971 call the police, shut the reopen after CNC to open, call the police eliminate! Ask guidance to maintain ~ ! Answer: The power source that may be I/O card or jumper become loose. 11, excuse me 506 of FS21T system, 507 call the police what to express (the numerical control lathe of the system of a FS21T of FS21T) my company switchs on the mobile phone to call the police namely 506, 507, excuse me of FS21T system 506, 507 call the police what to express, how to solve? Answer: 506OVERTRAVEL:+NExceededthen-thaxis+sidehardwareOT.

507OVERTRAVEL:-NExceededthen-thaxis-sidehardwareOT.

Whether does hardware exceed Cheng to appear at the same time? - > was PMC started? 12, the position shows (FANUC-0M) position shows trouble, the position shows by decimally before hind 3 turn into 4 answer: Parameter revises: No.

0001#0SCW1 instead 0 can CNC Milling CNC Machining